Edge Solutions
CDS — Clinker Detection System + ITM Connect
“Hear the clinkers fall — quantify fouling shedding before it damages the floor.”
CDS — Clinker Detection System
- Records every clinker that hits the boiler floor: when it landed, which floor zone it hit and how big it was.
- Ties each impact to the sootblower that was running when the deposit let go, so every sootblower has a measured count of clinkers per blow.
- Shows where the superheater is fouling, from which sootblowers shed the most.
- Tracks a chill-and-blow as it happens, and shows when the shedding has stopped.
- Gives the same measure for other cleaning methods, such as sonic horns and pulse-detonation cleaning.
- Built on ITM’s patented method — US 10,060,688 B2.
CDS — Clinker Detection App
Deposits build on the superheater until a sootblower, or a chill-and-blow, knocks them off. The large ones slide down the nose arch or fall straight from the tubes and hit the boiler floor, and nobody in the control room sees them land. CDS listens to the floor. Accelerometers on the floor’s supporting structure record each impact. Running on ITM Connect at the edge, the Clinker Detection App sizes the impact, places it in a floor zone, and ties it to the sootblower that was running. One measurement answers three questions: what hit the floor, which sootblowers are removing deposit, and whether a chill-and-blow is still shedding.

- Every impact, recorded — time, floor zone and size for each impact above the recording threshold.
- Size, in bands — each impact is reported as an equivalent weight and sorted into bands agreed for that boiler’s floor.
- Large-impact alarm — an impact in the upper bands raises an advisory bit at the moment it happens.
- Clinkers per blow — impacts are counted against the sootblower that was running, with the travel time down the nose arch allowed for.
- Shed rate — impacts per hour through a chill-and-blow, with a flag when the rate stays below a set level.
- Publishes it to the mill — the alarm, the shed rate and the sootblower figures go to the DCS, the sootblowing system and the historian.
At a glance: Accelerometers on the floor’s supporting structure · the floor divided into zones · size reported as equivalent weight at 30 m · three size bands · every impact tied to a sootblower · impacts per hour through a chill-and-blow · advisory beside the boiler’s own alarms.
Measuring at the floor is the differentiator. Other fouling measurements look at what is on the tubes. CDS measures what comes off them, at the moment it lands. The system is calibrated on the boiler itself: known weights are dropped from the access ports below the nose arch onto the bare floor during an outage, and the response of each sensor is recorded with the zone each weight lands in. The floor is divided into zones because it does not answer the same everywhere: floor tubes are stiffer near the walls than in the middle. After that, an impact is reported as an equivalent weight falling 30 meters, about 100 feet. It is a relative size and not a weighing, and it is enough to tell a nuisance from a clinker that can deform a floor tube.

Why falling clinkers matter
Clinkers are the masses of ash deposit that form around superheater tubes. Some reach the size of a small car, and they can fall up to 150 feet before they hit the floor. The larger a deposit grows before it comes off, the harder it lands. A boiler with a history of floor-tube damage faces unplanned tube replacements at outages, and a damaged floor tube raises the exposure to a smelt-water explosion.
Operators have two tools against deposits: sootblowing and the chill-and-blow. Both are run without a direct measure of what they remove. A sootblower that runs is assumed to be a sootblower that cleans, and a chill-and-blow is ended on judgment, because there has been no way to know when the shedding is over.


One floor. Three answers.
The same impact record serves the operator, the sootblowing strategy and the outage plan. A count of what each sootblower knocks down needs no model of the boiler, and it rests on one measurement that can be checked: something hit the floor, here, at this time.

What hit the floor
Every impact large enough to matter is recorded with its time, its floor zone and its size band, and the large ones raise an alarm as they land.

Which sootblowers earn their steam
Each impact is counted against the sootblower that was running when the deposit let go. A sootblower that sheds a lot is working a fouled area; one that sheds nothing is blowing clean tubes.

When the chill-and-blow is done
During a chill-and-blow the boiler is off liquor while the deposits are cooled and blown. The app counts impacts per hour through the event, and shows the rate rise, peak and die away.
What goes on the boiler
CDS adds a small number of sensors under the floor and reads one signal the mill already has. Nothing is installed inside the furnace.
Floor accelerometers
Sootblower status
ITM Connect at the edge
Proven on a recovery boiler
CDS was developed with a major pulp and paper producer for a recovery boiler with a history of floor-tube damage, and was presented at the International Chemical Recovery Conference in 2017. The mill strengthened the floor-tube supports and installed CDS to see what was landing. A finite element model of the floor tubes, checked against the calibration drops, related clinker size to floor-tube deformation and gave that boiler its three size bands.
- Large impacts were identified and traced to their source by matching them with sootblower operation.
- During a chill-and-blow, most of the shedding came from two groups of sootblowers, and two sootblowers near the roof and front wall removed the most per run.
- Four sootblowers shed very little, which showed where blowing was doing the least.
- The impact count showed the shedding rise, peak and stop through the shutdown, in real time.


Why it matters
Sootblowers can take up to 6 percent of the steam a boiler generates, so a small cut in unnecessary blowing adds up over a year, and less steam used means less fuel burned for the same output. Blowing fouled areas more often keeps clinkers small, which lowers the risk to the floor. A chill-and-blow that ends when the shedding ends puts the boiler back on liquor sooner. The same measurement can also be used to judge sonic horns and pulse-detonation cleaning.
CDS is advisory. It measures what reaches the floor, not the deposits still on the tubes, and it reports an equivalent size, not a weight. Small debris below the recording threshold is not counted, and the char bed affects the reading. It does not detect a tube leak, it is not part of the boiler’s protection or trip system, and the sootblowing sequence remains the mill’s decision.
A typical deployment
- Survey the floor. With the boiler drawings, mark the supporting structure, agree the zones and choose the sensor positions.
- Install. Mount the accelerometers under the floor and run them to the enclosure.
- Connect the sootblower status. Read which sootblower is running from the sootblower control system.
- Calibrate. During an outage, drop known weights from the access ports onto the bare floor and record where each one lands.
- Set the bands. Agree what size of impact is a concern for this floor; a finite element study of the floor tubes can be added.
- Baseline. Run through several sootblowing cycles to see the normal number of impacts for each sootblower.
- Hand over to the control room. Agree how the large-impact alarm enters the DCS alarm list and who acts on it.
- Review. After the first weeks and the first chill-and-blow, review the sootblowing sequence against what each sootblower removed.

References: published sources behind this page.
- T. Carlier and A. Jones, “Mitigating Recovery Boiler Damage and Increasing Sootblowing Efficiency with Clinker Detection System”, International Chemical Recovery Conference, 2017 — the system, the calibration, the size bands and the chill-and-blow results. Presentation slides.
- US 10,060,688 B2 — the ITM patent covering the detection method.
- T. Carlier and R. Welker, “Novel Clinker Detection System Reduces Boiler Fouling While Boosting Sootblowing Efficiency” — the clinker sizes, the sootblowing steam figure and the chill-and-blow use.
- H. Tran and others, “Removal of Recovery Boiler Fireside Deposits by Thermal Shedding”, Pulp & Paper Canada 94:11 (1993) — thermal shedding, as cited in the conference paper.
Part of ITM’s patented boiler monitoring family installed worldwide.
Next step: pairs with ITM Connect CleanPass, which measures the deposits still on the tubes.
Talk to an engineer: (844) 837-8797 · info@iTestSystem.com